E-Series structural evaluations
Structural Evaluations are documents from independent Professional Engineering firms that show compliance to the Florida Building Code’s structural requirements. The detailed drawings contained within these documents show placement of installation anchors based on the type of wall construction, Design Pressure (PSF) ratings based on unit size and structural joining charts when applicable. They also identify the testing protocol used to satisfy the wind borne debris requirements of the Florida Building Code for units with impact resistant glass.
If you are looking for evaluations for products other than E-Series, visit this page.
AUXILIARY FIXED • ARCHED CASEMENT • CASEMENT • AWNING • CASEMENT FIXED (DIRECT-SET) • DOUBLE-HUNG FULL FRAME • DOUBLE-HUNG PICTURE AND TRANSOM • HINGED PATIO DOOR & SIDELIGHT - INSWING • HINGED PATIO DOOR & SIDELIGHT - OUTSWING • HINGED PATIO DOORS - OUTSWING • HINGED PATIO DOOR TRANSOM - OUTSWING • GLIDING / FRENCH GLIDING PATIO & SIDELITE • MULLING • JOINING ENGINEERING ANALYSIS
Arch casement window (non-thermally broken frame)
Double-hung picture & transom full-frame
Hinged patio door & sidelight - inswing
Hinged patio door transom - inswing
Joining engineering analysis
- Joining - E-Series - LVL Wood - 1 x 3.5 - FL15267.4
- Joining - E-Series - LVL Wood - 1 x 5 - FL15267.6
- Joining - E-Series - LVL Wood - 2 x 3.5 - FL15267.5
- Joining - E-Series - LVL Wood - 2 x 5 - FL15267.7
- Joining - E-Series - Structural Steel - 1 x 3 x 18 Tube - FL15267.3
- Joining - E-Series - Structural Steel - 2 x 4 x .25 Tube - FL15267.1
- Joining - E-Series - Structural Steel - 2 x 4 x 1.25 Tube - FL15267.2